It is trained to connect genotype, blood biochemistry and population-level traits.
Blood tests,
connected to genetics.
Our model reads standard blood-test values alongside DNA variants, and is trained to connect genotype, blood biochemistry and population-level traits.
Reads blood biochemistry alongside DNA.
The model takes 28 standard blood-test values together with DNA variants, gene annotations, pathways and tissues.
On public survey data, the first version fills in a hidden blood value better than guessing the average, but a simple linear model is still ahead. The figures are below.
Nothing the model outputs should be used for diagnosis or treatment.
Standard blood-test values the model reads
Pathways the model reads
Tissues the model reads
More than above or below.
A standard blood test tells you where a number sits. We are building the model to tell you what it means for you, why it is there, and what would change it.
Standard testReads each marker on its own
Reads the whole panel
It sees how markers move with each other, not one number at a time.
Early version builtStandard testOne range for everyone
Your own normal
What is normal for you, given your genes, age, sex and history.
In developmentStandard testIn range or out of range
Flags what a range misses
A value that is in range but wrong for you, or a combination that is off when every value passes.
In developmentStandard testTells you what is high or low
Explains why
A gene, a nutrient, absorption, a medication, or another organ pulling the number there.
In developmentStandard testA snapshot
Where it is heading
It follows a marker across panels and flags it before it crosses the line.
In developmentStandard testEnds at the result
The next step
Which test would settle the question, and what change would move the number for someone with your genes.
In developmentStandard testBlood and DNA as separate tests
Blood and DNA together
A variant explains a blood value, and a blood value shows whether a variant is actually acting.
Early version builtStandard testOne person, one result
New discoveries
Relationships between genes, nutrients and biomarkers found across many people.
In development
Illustrations are conceptual, not model output. These are development goals, not a clinical service, and nothing here is a diagnosis.
What AI can read from a blood sample.
Research groups have shown that models can find far more in blood than a reference range reveals. These studies are why we are building in this direction.
- Blood count
18–24months earlier
Subtle changes in a routine blood count picked out people at higher risk of bowel cancer 18 to 24 months before diagnosis.
Holt et al. · NIHR Open Research, 2023 - Routine panel
25routine tests
A model reading 25 routine blood tests gave a cancer risk score for patients seen by their family doctor.
Soerensen & Christensen · Clin Chem Lab Med, 2021 - Biological age
9blood values
Nine routine blood values combine into a “phenotypic age” that was linked to mortality risk beyond a person’s actual age.
Levine et al. · Aging, 2018
- Proteins
~3,000proteins
Blood proteins measured in 41,931 people predicted the 10-year risk of 67 diseases better than standard clinical information.
Carrasco-Zanini et al. · Nature Medicine, 2024 - Small molecules
100,000+people
A neural network reading blood metabolites predicted the risk of more than 20 conditions, and added to standard clinical measures for eight.
Buergel et al. · Nature Medicine, 2022 - Cell-free DNA
50+cancer types
DNA fragments in blood, read with machine learning, signalled cancer across more than 50 types with 99.5% specificity. Overall sensitivity was 51.5%.
Klein et al. · Annals of Oncology, 2021 - Cell images
18,000+cell images
A neural network trained on white-blood-cell images recognised leukaemia cells as well as human examiners.
Matek et al. · Nature Machine Intelligence, 2019
Independent published research. These are other groups’ results, not GENODYNLABS model performance, and we do not offer any of them as a test. One sample can carry all of these layers; our own work starts with routine values and DNA.
Built. Being evaluated.
The blood component is an early building block. It learns how the values in a panel move together, and it is tested on public survey data and on a simulated population. It is not a diagnostic.
SnapshotResults in this section are as of this date.
Checks the report
Results are read from structured lab exports. Units are converted, below-detection results and reference ranges are kept, and a test that was not run stays missing instead of being treated as normal.
One entry per measurement
Each result enters the model with what was measured, its value, when it was taken and whether the person was fasting.
Learns the panel
It is trained by hiding a measured value and predicting it from the others, so it learns how blood values move together.
Links to DNA
The aim is to share this representation with the genetics network, so blood values can act as context for what a variant does. That integration is still being validated.
It outputs an estimate with a range for each value. It does not output disease probabilities, and nothing here is a diagnosis.
Filling in a hidden blood value
One measured value is hidden and predicted from the rest of the panel. The bars show the average error over 28 blood tests, in standard units. Shorter is better.
- Guess the average
- Linear regression
- GENODYNLABS
| Test | Guess the average | Linear regression | GENODYNLABS |
|---|---|---|---|
| Same survey years (539 adults held out) | 1.226 | 0.924 | 1.016 |
| Later survey years (5,274 adults) | 1.287 | 1.058 | 1.104 |
Public CDC NHANES survey data; the later survey years were never used in training. The component beats guessing the average, but a plain linear regression is still ahead on both tests, so it has not yet earned its place over the simpler method. This measures reconstruction of lab values, not disease prediction.
Does it know how sure it is?
Each estimate comes with a range meant to contain the true value 90% of the time. This is how often it did.
| Test | Coverage |
|---|---|
| Same survey years (15,035 hidden values) | 90.1% |
| Later survey years (145,357 hidden values) | 88.3% |
The ranges were calibrated on separate people from the same survey years, then checked here. Coverage slips a little on the later survey years, which used a different laboratory instrument.
Connecting blood values to DNA.
How much of a blood value can be explained from DNA is tested on a population of simulated people built on real genome positions, where the true effects are known. These results show the method works where the truth is known. They are not evidence of accuracy in real people.
What each kind of genetic effect adds
Share of the variation in 55 simulated blood tests explained on held-out simulated people, as each kind of effect is added to the model.
| Model | Mean R-squared |
|---|---|
| Age, sex, BMI and medication only | 0.153 |
| + each variant on its own | 0.296 |
| + variants acting together | 0.300 |
| + variants that depend on diet or body state | 0.316 |
| + remaining effects | 0.318 |
| Standard polygenic score | 0.281 |
| Highest possible | 0.331 |
Mean R² over all tests. Most of the gain beyond a polygenic score comes from variants whose effect depends on diet or on the state of the body.
Where non-additive effects matter most
The eight simulated tests that gained most. Each track runs from a standard polygenic score to the model, with the highest possible score marked.
- Polygenic score
- GENODYNLABS
- Highest possible
| Test | Polygenic score | GENODYNLABS | Highest possible |
|---|---|---|---|
| Folate | 0.251 | 0.404 | 0.408 |
| Ferritin | 0.420 | 0.546 | 0.554 |
| LDL cholesterol | 0.331 | 0.463 | 0.523 |
| ApoB | 0.329 | 0.448 | 0.503 |
| Omega-3 index | 0.200 | 0.286 | 0.291 |
| Vitamin D | 0.413 | 0.486 | 0.490 |
| Vitamin B12 | 0.339 | 0.398 | 0.403 |
| Iron | 0.121 | 0.180 | 0.192 |
R² on held-out simulated people. These tests carry planted gene-by-diet and combination effects, for example a folate gene whose effect depends on leafy-green intake.
The market we serve.
Clinical laboratories is a core market for us: one of four industries, together estimated at $606B worldwide in 2026, that the model is built to serve.
Clinical laboratories · 2026 global estimate
Total underlying industry market (TAM) · global estimates (2026)
- GenomicsCore market$22.6B
- Clinical laboratoriesCore market$229.9B
- Pharmaceutical R&DKey expansion$308B
- Medical imagingFuture expansion$45.5B
Global estimates for 2026. These are the sizes of the industries our model is built to serve, not GENODYNLABS revenue.
